Grid Generation & Consumption Mix Explorer

Life-cycle emission factors for US balancing authorities, hour by hour. About this tool — methodology, assumptions, verification and sources.

What this is for

To give life-cycle practitioners a defensible hourly carbon intensity for the US grid — one where the accounting boundary is chosen deliberately rather than inherited, every figure traces back to the process it came from, and the limits are stated rather than left to be discovered.

The same grid yields different, equally correct numbers depending on what you are asking. A region that generates cleanly can consume dirtily, and a factor that is right for a corporate inventory is wrong for a claim about additional renewables. Choosing the boundary is the work; this tool makes the choice explicit and shows what it costs.

The boundaries themselves are set out at the foot of this page — the hourly ones built here and the annual ones published by eLCI.

Click a region on the map. The panel beside it plots that region on whichever boundary you select, and the kg CO₂e / MWh toggle switches between the carbon and the energy behind it — the two are the same hours seen through different weights.

kg CO₂e/MWh
< 150
150–300
300–450
450–600
600–750
750–900
900+
no data

Select a region on the map to see its factors plotted.

How sensitive is your GWP reporting to location specificity and real time consumption of electricity? →Most LCAs embed a national-average grid factor from whichever release was current when the study was done. Correct a published footprint for the grid the plant actually runs on — or check first whether location moves your product at all.Is the price of electricity related to use of renewables? →2024 average retail rates against this project’s hourly carbon intensity and each region’s observed renewables share — mapped side by side, with the correlations.Explore residual mixes — what’s in them and who gets to take credit →Every clean megawatt-hour mints a certificate, and whoever retires it owns the claim. What the certificate registries actually left unclaimed in 2023, fuel by fuel — with a worked example, the definitions, and how far those pools sit from eLCI’s residuals.Is this grid getting cleaner, and is the number you cited last year still right? →A factor here is a photograph of a grid that keeps moving. This page holds the record: what each region generated week by week and how the fuel mix shifted, how much energy was generated and consumed, and how price and carbon have moved together quarter by quarter. It also separates the three reasons a figure changes — the grid moved, the window the average covers grew, or a data release was swapped underneath it — because on any single page those look identical.

Hourly, from this project

Built hour by hour from EIA-930, so they follow the grid as it actually ran. EIA-930

Hourly generation
What was generated inside the region this hour. No imports, no losses — the narrowest boundary and the one with the least assumption in it.
Hourly consumption
What was consumed here, following imports one hop to whoever generated them. This is eLCI's own method applied to observed hourly flows.
Hourly consumption, multi-hop
The same flows solved as a network: power reaching you through a neighbour takes the emission factor of whoever actually generated it, not the neighbour's. For import-dependent regions this differs from the line above by up to 160%.
Hourly consumption, at user
Carried from the transmission system to the socket. Every unit lost on the way still had to be generated, so intensity per unit delivered is higher — 2.5% to 4.2% depending on the region. This is the boundary an end user actually consumes at.

Annual, published by eLCI

Fixed for a release by eLCI, so they do not track recent change — but they are the citable figures. eLCI

Generation mix
The annual version of the generation basis.
Consumption mix, at grid
Imports included, measured where power leaves the transmission system.
Consumption mix, at user
The same, carried to the socket — transmission and distribution losses included, so the number is higher.
Residual mixes
What is left after contracted renewables are claimed by their buyers. If someone else holds the certificate for that wind farm, you cannot also count it; this is the boundary that says so.

Boundary. Attributional average at balancing-authority scale — not marginal, and not supplier- or contract-specific. Busbar unless the framing says otherwise. Assumptions · Sources · Built from EIA-930 · eLCI · eGRID

Disclaimer. Academic project. US Government data used responsibly; outputs used at your own risk, with no responsibility or liability accepted. Opinions are my own and reflect no position of my employer.